Mammography Positioning for the ARRT Exam: CC, MLO, and Special Views

Mammography positioning is the largest single topic on the ARRT Mammography exam: it sits inside Mammographic Positioning and Procedures, worth 39 of 115 scored questions, and ARRT bases the questions on the ACR Mammography Quality Control Manual's clinical image quality standards, starting with the craniocaudal (CC) and mediolateral oblique (MLO) views (ARRT Mammography Examination Content Specifications 2025).

Why does positioning carry so much of this exam?

Because the specifications put it where the questions are. Procedures is worth 65 of 115 scored questions, split between Anatomy, Physiology, and Pathology (26) and Mammographic Positioning and Procedures (39) (ARRT Mammography Examination Content Specifications 2025). Positioning alone is about a third of the scored exam — 39 divided by 115 — which makes it larger than the whole Patient Care section (20) and the whole Image Production section (30) (ARRT Mammography Examination Content Specifications 2025).

Candidates meet this test under several names — the ARRT Mammography exam, the mammography registry exam, and the mammo registry — but the positioning standard is the same: the mammographer is expected to know positioning as presented in the ACR Mammography Quality Control Manual — Clinical Image Quality (ARRT Mammography Examination Content Specifications 2025). The exam judges your images the way the ACR standards judge them, then asks which special view fixes the problem.

One caution: approximately six items in the positioning section cover the standard views, CC and MLO (ARRT Mammography Examination Content Specifications 2025). Six is the floor for CC and MLO, not the ceiling for positioning — the rest of the 39 covers the special views, special patient situations, imaging examinations, and interventional preparation in the same subcategory (ARRT Mammography Examination Content Specifications 2025).

What does a well-positioned CC view have to show?

The craniocaudal view is the exam's medial-tissue view. The CC projection best visualizes the subareolar, central, medial, and posteromedial aspects of the breast, and it is poor at visualizing the lateral breast — which is why including the medial breast on the CC is critical (Mammographic Positioning, Chapter 7). Judge a CC image against these criteria:

  • Medial tissue included. The medial and lateral aspects of the breast must both fall inside the collimated area, and the medial side is the one you cannot recover on the MLO (Mammographic Positioning, Chapter 7).
  • Nipple in profile, and centered without sacrificing tissue. The nipple should be in profile and centered on the image, but you do not eliminate breast tissue to center it (Mammographic Positioning, Chapter 7).
  • Posterior depth that matches the MLO. The CC should include, within 1 cm, the posterior nipple line measurement of the MLO (Mammographic Positioning, Chapter 7).
  • Pectoral muscle is a sometimes finding, not a requirement. The pectoralis major is seen in approximately 30% to 40% of CC cases, and if the pectoral muscle is seen on every case, medial breast tissue is probably being lost (Mammographic Positioning, Chapter 7).
  • Detector height set from the breast, not the machine. Position the detector at the level of the raised inframammary crease (Mammographic Positioning, Chapter 7).

The exam's favorite CC trap is the trade-off in the second and fourth bullets. A CC that shows a neat strip of pectoral muscle and a perfectly centered nipple can still be the wrong answer if it was bought by cutting medial tissue. Tissue inclusion outranks cosmetics in the ACR framing: clinical assessment of positioning compares the retroglandular coverage between the CC and MLO views, starting with the PNL check (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography).

What does a well-positioned MLO view have to show?

The mediolateral oblique view is the coverage view. The MLO demonstrates the extreme posterior breast and the upper-outer quadrant, and the detector must be parallel to the pectoralis muscle, at an angle that can vary from 30 to 60 degrees depending on the patient (Mammographic Positioning, Chapter 7). Judge an MLO image against these criteria:

A concave pectoral edge, a muscle that stops well above the nipple line, or a breast that sags on the image are the classic MLO faults the exam puts in front of you. Each one has a positioning cause — detector angle not parallel to the muscle, detector set too high, or the breast not lifted and supported — and the questions usually ask for the cause or the correction, not just the name of the fault.

CC and MLO side by side: what each view is judged on

Check CC MLO
Tissue it must prove Medial and posteromedial tissue; subareolar and central breast (Mammographic Positioning, Chapter 7) Posterior breast and upper-outer quadrant, including the axillary tail region (Mammographic Positioning, Chapter 7)
Known blind spot Lateral breast, especially the axillary tail (Mammographic Positioning, Chapter 7) Anterior, central, and medial tissue is distorted compared with the CC (Mammographic Positioning, Chapter 7)
Pectoral muscle Seen in about 30% to 40% of properly positioned cases; seeing it every time suggests medial tissue is being lost (Mammographic Positioning, Chapter 7) Wide superiorly, convex anterior border, extending to or below the nipple line (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography; Mammographic Positioning, Chapter 7)
Shared measurement PNL within about 1 cm of the MLO measurement (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography) PNL within about 1 cm of the CC measurement; drawn perpendicular to the muscle, usually near 45 degrees (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography)
Nipple In profile and centered, without eliminating tissue to achieve it (Mammographic Positioning, Chapter 7) In profile where possible, with the breast held up and out (Mammographic Positioning, Chapter 7)

Read the table as a division of labor: the CC proves the medial breast the MLO distorts; the MLO proves the posterior and upper-outer breast the CC cannot reach. The specifications also test clock position, quadrants, and triangulation inside Anatomy, Physiology, and Pathology (ARRT Mammography Examination Content Specifications 2025) — positioning and localization grade each other on this exam.

Which special view solves which problem?

The specifications name 14 views: CC, MLO, mediolateral (ML), lateromedial (LM), exaggerated craniocaudal (XCCL and XCCM), cleavage (CV), axillary tail (AT), tangential (TAN), rolled (RL, RM, RS, RI), implant displaced (ID), nipple in profile, anterior compression, spot compression, and magnification (ARRT Mammography Examination Content Specifications 2025). Exam questions rarely ask you to recite that list. They describe a problem and ask which view answers it:

Problem in front of you View Why it works
Lateral tissue or axillary tail cut off on the CC Exaggerated CC, lateral (XCCL) The exaggerated CC is the view for posterolateral tissue the standard CC missed (Mammographic Positioning, Chapter 7)
Deep medial tissue not fully shown Cleavage view (CV) The cleavage view is the exaggerated view aimed at extreme medial tissue (Mammographic Positioning, Chapter 7)
A density that may be overlapping tissue, not a real lesion Spot compression A small paddle compresses one area to spread overlapping tissue and define the borders of a possible mass (Mammographic Positioning, Chapter 7)
Calcifications or a mass margin that needs detail Magnification Magnification improves resolution and better visualizes calcifications and the borders of lesions (Mammographic Positioning, Chapter 7)
Palpable finding, or a finding that may be in the skin Tangential view (TAN) The tangential view is used for a palpable abnormality, projecting the area of concern so its borders and depth can be judged (Mammographic Positioning, Chapter 7)
Finding seen on one view that needs a true 90-degree partner ML or LM The true lateral views are listed alongside CC and MLO in the specifications and pair with triangulation to place a finding in three dimensions (ARRT Mammography Examination Content Specifications 2025)
Patient with breast implants Implant displaced (ID) The implant displaced view images the tissue anterior to the implant; augmentation and implanted devices are also named special patient situations in the specifications (ARRT Mammography Examination Content Specifications 2025; Mammographic Positioning, Chapter 7)
Tissue that overlaps in the same place on repeat views Rolled views (RL, RM, RS, RI) Rolling shifts the tissue so superimposed structures separate; rolled views are a named part of the specifications' views list (ARRT Mammography Examination Content Specifications 2025)

The pattern to carry into the exam: every special view exists because a standard view has a named blind spot. If you can state the blind spot, you can usually choose the view. If a question names the view instead, reverse it — state what tissue or problem that view was built for, and check the scenario against it.

How does the exam test positioning judgment?

Mostly as image evaluation, which the specifications also test inside Image Production. Technique and image evaluation cover judging positioning, compression, exposure, contrast, sharpness, noise, artifacts, collimation, and motion on a finished image (ARRT Mammography Examination Content Specifications 2025). So a positioning weakness can cost you in two sections: the 39-question positioning subcategory itself, and the image-evaluation questions that show you a flawed image and ask what went wrong.

Practice the judgment in the order a reviewer uses. First, coverage: does the PNL check pass, within about 1 cm between the views (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography)? Second, the muscle: convex and reaching the nipple level on the MLO, present but not forced on the CC (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography; Mammographic Positioning, Chapter 7). Third, the nipple and the fold: nipple in profile without sacrificed tissue, breast lifted rather than drooping on the MLO (Mammographic Positioning, Chapter 7). Fourth, the fix: if tissue is missing or a finding is unresolved, name the special view built for that exact gap, using the table above.

Drill criteria and corrections together, in image-based sets, rather than memorizing view names alone: the exam is checking whether you can evaluate a positioned image against written criteria and choose the corrective view.

What this article can't do for you

This guide can give you the criteria: the PNL rule, the pectoral standards, and which special view answers which problem. It cannot tell you whether you can apply those criteria under exam conditions — spotting the concave muscle, the short PNL, or the wrong corrective view in a set of similar answer choices, 39 questions deep into the largest section of the test. Reading criteria is not the same as judging images against them.

That judgment is what practice builds. Upward Prep's free 10-question ARRT Mammography diagnostic gives you instant feedback, cited explanations for every answer, and a breakdown by section, so you can see whether positioning is a strength or the section to fix first. Try the free ARRT Mammography practice test →

Frequently asked questions

mammography positioning

Mammography positioning is the 39-question core of the ARRT Mammography exam: Mammographic Positioning and Procedures is the largest subcategory in the specifications, and ARRT expects positioning knowledge as presented in the ACR Mammography Quality Control Manual — Clinical Image Quality (ARRT Mammography Examination Content Specifications 2025). Approximately six items in that section cover the standard views, CC and MLO (ARRT Mammography Examination Content Specifications 2025).

cc mlo views

The CC and MLO views are the two standard mammography views. The CC best visualizes the subareolar, central, medial, and posteromedial breast, while the MLO demonstrates the extreme posterior breast and upper-outer quadrant (Mammographic Positioning, Chapter 7). They are judged as a pair: the posterior nipple line on the CC should be within about 1 cm of the PNL on the MLO (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography).

mammography image quality

Mammography image quality is judged on the finished image across positioning, compression, exposure, contrast, sharpness, noise, artifacts, collimation, and motion, per the evaluation list in the ARRT specifications (ARRT Mammography Examination Content Specifications 2025). For positioning specifically, the ACR standard compares retroglandular coverage between the CC and MLO views, starting with the posterior nipple line check (ACR–AAPM–SIIM Practice Parameter for Determinants of Image Quality in Mammography).

arrt mammography practice test

A useful ARRT Mammography practice test weights positioning the way the real exam does: Mammographic Positioning and Procedures is 39 of 115 scored questions, inside a Procedures section worth 65 (ARRT Mammography Examination Content Specifications 2025). Check any practice set against that split, and prefer explanations that cite the ACR positioning criteria the specifications point to (ARRT Mammography Examination Content Specifications 2025).